Comfort Line Products CL 250-C Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach PC / Workstation Barebones Comfort Line Products CL 250-C herunter. BST/FBST COMFORT LINE Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - COMFORT LINE

Curved Sliding DoorsBST/FBSTCOMFORT LINE

Seite 2 - Curved Sliding Doors

10DORMA BST COMFORT LINE FBST COMFORT LINE Connection diagram Safety equipmentBST/FBST, GB

Seite 3 - Basic configurations

SEITE A4 x 0,75 mm23 x 0,75 mm22 x 0,75 mm23 x 1,5 mm216 AL1 NPE1234510 x 0,75 mm2**6 mm2 equipotential bonding* required twice with BST 360°11DORMA

Seite 4 - Technical Data

12 System accessoriesProgram switches Pushbuttons Emergency pushbuttonDesignation Specification Installation system Order No.Program switch PG-S2

Seite 5 - Accessories

13PushbuttonsDesignation Specification Installation system Order No.PushbuttonsPushbutton Single-pole changeover contact, standard frame, whi

Seite 6 - Configurations

14 System accessoriesActive infrared safety sensor Radar motion detectors Combined sensorsActive infrared safety sensorDesignation Specification

Seite 7

15Designation Specification Combined sensorsActiv8 One on / Activ8 Three onTo activate (open) and pro-tect automatic sliding doors. This system is de

Seite 8 - Façade connections

Door ControlAutomaticMovable WallsSecurity Time and Access (STA)Glass fittings and Accessorieswww.dorma.comDORMA GmbH + Co. KG DORMA Platz 1 D-58256 E

Seite 9

2DORMA BST COMFORT LINE FBST COMFORT LINE Curved Sliding DoorsDORMA BST COMFORT LINE automatic curved sliding doors are the perfect answer to providin

Seite 10 - BST/FBST, GB

3Basic configurationsHalf-circleFull circle insideoutsideinsideoutsideBST/FBST, GB

Seite 11 - SEITE 15-1

Power consumption, max. 250 WPower consumption, average 30 W Supply voltage/frequency 230 V / 50 – 60 HzExternal power supply 27 V DC / 2 A

Seite 12 - Program switch

DORMA BST COMFORT LINE FBST COMFORT LINE AccessoriesLocking device Electro-mechanical locking device X XFail-safe via emergency power supply uni

Seite 13 - Emergency pushbutton

LHHSHBSLWLWBSRR6DORMA BST COMFORT LINE FBST COMFORT LINE ConfigurationsHalf-circle and full-circle configurationsDORMA FBST with approval for applicat

Seite 14 - Radar motion detectors

7LH62SHSSB2062BNominal radius (r)Internal radiusDrum wall and sliding panel with sealing profilesPanels with centre sealsAluminium girder with conne

Seite 15 - Combined sensors

8DORMA BST COMFORT LINE FBST COMFORT LINE Façade connectionsFaçade connection 360°Façade connection 180°BST/FBST, GB

Seite 16

9DORMA BST COMFORT LINE FBST COMFORT LINE Floor guides Floor ringsFFLFFLCFFLFFLCFFLFFLCFFLFFLC****.FFLFFLFFL**upper edge of unfinished floor The desig

Kommentare zu diesen Handbüchern